DOE R-5: A Window of the Future

Reduce the Average Heat Loss Through Windows by as Much as 40 Percent!

The DOEís R-5 Windows Volume Purchase Program is about more than just saving money

Cold and Mixed Climates like the Northeast demand performance form their Windows! R 5 Windows the top tier of energy efficient windows and are highly insulating!
DOE R5

R5 WIndows have an R-value of 5 (or a U-factor of around 0.2)

The R Factor

indicates a windows resistance to Heat Flow (The higher the number  the more effective the insulting factor).

The U Value

measures the rate of heat transfer (The lower the U factor, the better a window insulates.)

The US Department of Energy’s Building Technologies Program (BTP) is coordinating a volume purchase of R5 windows and low-e storm windows, to expand the market of these high efficiency products.

Price has been the principal barrier to more widespread market commercialization. The aim of this volume purchase initiative is to work with industry and potential buyers to make highly insulated windows more affordable.

Kasson and Keller, Inc is proud to be selected as a participant in the BTP VPP. We provide a wide array of products accepted under the DOE – R5 criteria for windows.
DOE-R5 Certified Windows

A Superior Window for the Cost

NFRC Testing Chart
Department of Energy R5 Program
Triple Glazing Package

Effective Date: March 1, 2010

400/4000 Double Hung

U-FACTOR SHGC VT CR DBL LOW E GAS
SSB WITHOUT GRIDS 0.21 0.21 0.39 71 Y DOUBLE ARGON
SSB WITH GRIDS 0.21 0.19 0.35 71 Y DOUBLE ARGON
DSB WITHOUT GRIDS 0.22 0.21 0.39 69 Y DOUBLE ARGON
DSB WITH GRIDS 0.22 0.19 0.34 69 Y DOUBLE ARGON

 

700/7000 Casement

U-FACTOR SHGC VT CR DBL LOW E GAS
SSB WITHOUT GRIDS 0.20 0.19 0.35 74 Y DOUBLE ARGON
SSB WITH GRIDS 0.21 0.18 0.32 74 Y DOUBLE ARGON
DSB WITHOUT GRIDS 0.22 0.19 0.35 74 Y DOUBLE ARGON
DSB WITH GRIDS 0.22 0.18 0.32 74 Y DOUBLE ARGON

700/7000 Awning

U-FACTOR SHGC VT CR DBL LOW E GAS
SSB WITHOUT GRIDS 0.20 0.19 0.35 75 Y DOUBLE ARGON
SSB WITH GRIDS 0.20 0.18 0.32 75 Y DOUBLE ARGON
DSB WITHOUT GRIDS 0.21 0.19 0.35 74 Y DOUBLE ARGON
DSB WITH GRIDS 0.22 0.18 0.32 74 Y DOUBLE ARGON

400/4000 Picture Window

U-FACTOR SHGC VT CR DBL LOW E GAS
SSB WITHOUT GRIDS 0.19 0.22 0.41 73 Y DOUBLE ARGON
SSB WITH GRIDS 0.19 0.20 0.37 73 Y DOUBLE ARGON
DSB WITHOUT GRIDS 0.20 0.22 0.41 73 Y DOUBLE ARGON
DSB WITH GRIDS 0.21 0.20 0.37 73 Y DOUBLE ARGON

400/4000 Rolling

U-FACTOR SHGC VT CR DBL LOW E GAS
SSB WITHOUT GRIDS 0.21 0.22 0.40 70 Y DOUBLE ARGON
SSB WITH GRIDS 0.21 0.19 0.36 70 Y DOUBLE ARGON
DSB WITHOUT GRIDS 0.22 0.21 0.40 68 Y DOUBLE ARGON
DSB WITH GRIDS 0.21 0.20 0.35 70 Y SINGLE KRYPTON

DOE-R5
Glass Packages

Insulated triple glass
Double high-performance Low E coating
Double argon gas filled between panes
High performance spacer system
NFRC Thermal Performance data without grids
Glass Type: DOE-R5
U-Value: 0.2
SHGC: 0.2
VLT: 0.36